Updated 11 November 2026 in line with IMDG Code Amendment 42-24.

Image of “Flaming” cocktails is by Nik Frey (niksan).

What is Flashpoint?

Flashpoint means the lowest temperature of a liquid at which its vapour forms an ignitable mixture with air.

Flashpoint gives a measure of the risk of formation of explosive or ignitable mixtures when the liquid escapes from its packing.

A flammable liquid cannot be ignited so long as its temperature remains below the flashpoint.

How Flashpoint is tested?

A specified quantity of the liquid is introduced into a receptacle at a temperature well below the flashpoint to be expected, then slowly heated; periodically, a small flame is brought near to the surface of the liquid. The flashpoint is the lowest temperature at which a “flash” is observed.

The test methods can be divided into two groups, depending on the use in an apparatus of an open receptacle (open-cup methods) or a closed one which is only opened to admit the flame (closed-cup methods). As a rule, the flashpoints found in an open-cup test are a few degrees higher than in a closed-cup test.

 

How Flashpoint changes the rules to load dangerous goods on board ships?

SOLAS Regulation II-2/19.4 requires flag state administration to provide the ship with a document as evidence of compliance of construction and equipment with the requirements of regulation II-2/19 of SOLAS 1974 Convention. This document of compliance (DOC) certifies which cargo hold is permitted to carry which class of dangerous goods.

For cargoes with flashpoint below or above 23 Deg Celsius there is difference in permission and this is grouped as below.

  • Class 3 FP < 23°C
  • Class 3 FP ≥ 23°C to ≤ 60°C
  • Class 6.1 liquids FP < 23°C
  • Class 6.1 liquids FP ≥ 23°C to ≤ 60°C
  • Class 8 liquids FP < 23°C
  • Class 8 liquids FP ≥ 23°C to ≤ 60°C

SOLAS regulation II-2/19 does not permit class 4.3 liquids with a flashpoint below 23°C under deck or in enclosed ro-ro spaces (see UN/SCETDG/68/INF.25).

Below a sample section of DOCUMENT OF COMPLIANCE permitting dangerous goods having flashpoint below 60 Deg C in packaged form

Document of Compliance highlighting dangeorus goods with flashpoint below 60 Deg C
Document of Compliance highlighting dangerous goods with flashpoint below 60 Deg C

Declaration of Flashpoint

Section 5.4.1.4.3.7 of IMDG Code Amendment 42-24 states

“If the liquid dangerous goods to be transported have a primary or subsidiary hazard of class 3 and a flashpoint of 60°C or below (in °C closed-cup (c.c.)), the minimum flashpoint shall be indicated. Because of the presence of impurities, the flashpoint may be lower or higher than the reference temperature indicated in the Dangerous Goods List for the substance.”

As per this requirement, the flashpoint must be shown on the dangerous goods declaration for any liquid whose primary or subsidiary hazard is class 3, for example

  • Class 3
  • Class 4.3 liquids with subsidiary hazard class 3
  • Class 6.1 liquids with subsidiary hazard class 3
  • Class 8 liquids with subsidiary hazard class 3

One missing minus sign

A product with a flashpoint of −26°C c.c. typed on the DGD as (26°C c.c.) appears to be above 23°C. On paper it moves to PG III and to the 23°C to 60°C group of the Document of Compliance, and the container may be planned into a hold that is not approved for liquids below 23°C, or near sources of ignition on deck. A missing minus sign can change the stowage and may result in an accident. Check the sign against the SDS before the DGD is signed.

 


Discover more from IMDG Code Compliance Centre

Subscribe to get the latest posts sent to your email.

By Shashi Kallada

35 years in Merchant Shipping, Last 23 years working on IMDG Code. Ex Sailor, Ex Manager Global Dangerous Goods Maersk Line.

Leave a Reply

Discover more from IMDG Code Compliance Centre

Subscribe now to keep reading and get access to the full archive.

Continue reading